|
|
|
|
|
|
|
 
 
 
Railway compositive sheath signal cable
      This product is applied to transfer audio frequency signal under 500v AC rated voltage or below, fixed laying railway signal and some control line with auto equipment.
    This product has performance of shielding, it is applied to electrical railway area or other area with strong disturb.
    The long term allowed working temperature of cable core should be not more than 70oc.
    The environment for cable laying: PVC cable should be not less than 0oc, polyethylene sheath cable should be not less than ¨C10oc.
    Cable is allowed to the laying on line of any level difference, the bending radius should be not 15 times less than cable outside diameter when laying.


 1¡¢ Type, name, laying condition, dimensions £º
£¨attached with map£©
 2¡¢ Arranging sketch map for line order of star quad End A and order of cable End A
£º£¨attached with map£©
 3¡¢ Main technical condition £º
      1¡¢ Ideal shielding index £º
       Inductive voltage on cable sheath with 9 cores or below is 50~200v/km£»
       Inductive voltage on cable sheath with 12 cores or upwards £»
       The ideal shielding index of cable should be not more than 0.8.
      2¡¢ Compositive sheath £º
        £¨1£© Striped, longitudinal application, lapped seamed, and heat jointing for shape by plastic-aluminum-plastic compound, and extruding with polyethylene sheath.
        £¨2£© The compound tape of the compositive sheath should coupling in the whole cable length.
        £¨3£© Requirement of bonding strength; the bonding strength between compound tape and polyethylene sheath should be not less than 0.8N/Mm2.
      3¡¢ Electric performance index £º
£¨attached with map£©
 4¡¢ Delivery length £º£¨ the tolerance is ¡À0.5% £©
      1¡¢ The delivery length of cable with the length of 500m or above should be not less than 50% of the total length;
      2¡¢ We allow the cable delivery with the length of less than250m and more than 50m. The amount should be not more than 5% of the total delivery length;
¡¡¡¡ 3¡¢ According to customer¡¯s special requirement, both sides can negotiate for any length delivery.
 5¡¢ Cable outside diameter and weight
£¨attached with map£©

Product search

Product category list
Category 5 lan communicate data cable
Category 5e lan communicate data cable
Category 6 lan communicate data cable
Category 7 lan communicate data cable
 
HYA-solid dielectric unfilled cable
HYAC-self supported 8-shaped telecommunication cable
HYAT-solid dielectric filled cable
Railway plastic sheathed signal cable
Railway composite sheathed signal cable
Railway al-sheath signal cable
Steel core al-twisting line and al-twisting line
 
DQJ-1 powder static eliminator with ion wind
DQJ-2 powder static monitoring instrument
DQJ-3 antistatic annunciator of high materials position
Certificate of conformity
Copyright © 2005 Jiangsu Dongqiang Co.,Ltd All Rights Reserved