Nominal section mm2 |
structure diameter |
calculated section
|
outside diameter
mm |
DC resistance not more than /km |
calculated strain m |
calculated weight km |
delivery length not less than m |
aluminum |
steel |
aluminum |
steel |
total |
10/2 |
6/1.50 |
1/1.50 |
10.60 |
1.77 |
12.37 |
4.50 |
2.706 |
4120 |
42.9 |
3000 |
16/3 |
6/1.85 |
1/1.05 |
16.13 |
2.69 |
18.82 |
5.55 |
1.778 |
6130 |
65.2 |
3000 |
30025/4 |
6/232 |
1/2.32 |
25.36 |
4.23 |
29.59 |
6.96 |
1.131 |
9290 |
102.6 |
3000 |
35/6 |
6/2.72 |
1/2.32 |
34.86 |
5.81 |
40.67 |
8.16 |
0.8230 |
12630 |
141.0 |
3000 |
50/8 |
6/320 |
1/3.20 |
48.25 |
8.04 |
56.29 |
9.60 |
0.5946 |
16070 |
195.1 |
2000 |
50/30 |
12/2.32 |
7/2.32 |
50.73 |
29.59 |
80.32 |
11.60 |
0.5692 |
42620 |
372.0 |
3000 |
70/10 |
6/3.80 |
1/3.80 |
68.05 |
11.34 |
79.39 |
11.40 |
0.4217 |
23390 |
275.2 |
2000 |
70/40 |
12/2.72 |
7/2.72 |
69.73 |
40.67 |
110.40 |
13.60 |
0.4141 |
58380 |
511.3 |
2000 |
95/15 |
26/2.15 |
7/1.67 |
94.39 |
15.33 |
109.72 |
13.61 |
0.3058 |
35000 |
380.8 |
2000 |
95/20 |
7/4.16 |
7/1.85 |
95.14 |
18.82 |
113.98 |
13.81 |
0.3019 |
37200 |
408.9 |
2000 |
95/55 |
12/3.20 |
7/3.20 |
96.51 |
56.32 |
152.81 |
16.00 |
0.2992 |
78110 |
707.7 |
2000 |
Nominal section M©O |
structure diameter |
calculated section |
outside diameter
mm |
DC resistance not more than /km |
calculated strain m |
calculated weight km |
delivery length not less than m |
16 |
7/1.7 |
15.89 |
5.10 |
1.802 |
2840 |
43.5 |
4000 |
25 |
7/2.15 |
25.41 |
6.45 |
1.127 |
4355 |
69.6 |
3000 |
35 |
7/2.50 |
34.56 |
7.50 |
0.8332 |
5760 |
94.1 |
2000 |
50 |
7/3.00 |
49.48 |
9.00 |
0.5786 |
7930 |
135.5 |
1500 |
70 |
7/3.60 |
71.25 |
10.80 |
0.4018 |
10950 |
195.1 |
1250 |
95 |
7/4.16 |
95.14 |
12.48 |
0.3009 |
14450 |
260.5 |
1000 |
Electrical and mechanical performance:
1¡¢
Round al-line¡¯s resistance rate should be less than 0.028264¦¸.mm2/m after twisting
2¡¢
Round al-line¡¯s dielectric strength should be more than 95% of the minimum value of the dielectric strength of LY9 type in GB3955-83 after twisting
3¡¢
Dielectric strength of zinc-plated steel should be more than 1244N/mm2 after twisting |